How to change a high pressure sensor assembly on an Indesit Dishwasher

  1. Dishwasher
    How to change a high pressure sensor assembly on an Indesit Dishwasher
  2. Safety First:Remove the Plug from the Mains Socket
    Safety first 2
  3. Tools required:Phillips Screwdriver & a Socket for Jubilee Clips
    Phillips screwdriver & jubilee socket
  4. Indesit DI620 Integrated Dishwasher
    D1620 Door Image
  5. Lay the appliance on its side to expose the base
    DI620 Base 1a
  6. Using the phillips screwdriver remove the base retaining screws
    DI620 Base 2
  7. Remove further base retaining screws
    DI620 Base 3
  8. Carefully pull the base out a small amount
    DI620 Base 4
  9. Locate the overflow unit on the inside of the base
    DI620 Overflow Container 1
  10. Make a note of the wires and remove them now remove the base
    DI620 Overflow Container 2
  11. Using the jubilee socket spanner release the sump to pump jubilee clip
    DI620 HP Sensor Assembly 1
  12. Release the clip retaining the high pressure sensor assembly to the pump
    DI620 HP Sensor Assembly 2
  13. Grip the pump
    DI620 HP Sensor Assembly 3
  14. Remove the pump from the sump
    DI620 HP Sensor Assembly 4
  15. Remove the pump from the high pressure sensor assembly
    DI620 HP Sensor Assembly 5
  16. Make a note of the wires (a photograph is useful) 
    DI620 HP Sensor Assembly 6
  17. Remove the wire from the high pressure sensor assembly 
    DI620 HP Sensor Assembly 7
  18.  Wires removed
    DI620 HP Sensor Assembly 8
  19. From inside the appliance grip the lower spray arm retaining nut and release it
    DI620 HP Sensor Assembly 9
  20. Remove the lower spray arm
    DI620 HP Sensor Assembly 10
  21. Grip the lower spray arm support & unscrew it from the high pressure sensor
    DI620 HP Sensor Assembly 11
  22. Remove the lower spray arm support from the high pressure sensor assembly
    DI620 HP Sensor Assembly 12
  23. From the bottom of the appliance remove the high pressure sensor assembly
    DI620 HP Sensor Assembly 13
  24. High pressure sensor assembly removed
    DI620 HP Sensor Assembly 14
  25. Take the sensor assembly from its package ensuring its correct for the appliance
    DI620 High Pressure Sensor Assembly Image
  26. From the bottom of the appliance fit the new high pressure sensor assembly
    DI620 HP Sensor Assembly 13
  27. Replace the lower spray arm support to the new high pressure sensor assembly
    DI620 HP Sensor Assembly 12
  28. Tighten the lower spray arm support onto the new high pressure sensor assembly
    DI620 HP Sensor Assembly 11
  29. Replace the lower spray arm
    DI620 HP Sensor Assembly 10
  30. Tighten the nut retaining the lower spray arm
    DI620 HP Sensor Assembly 9
  31. Replace the wires to the high pressure sensor assembly
    DI620 HP Sensor Assembly 8
  32. Wires in place
    DI620 HP Sensor Assembly 6
  33. Fit the pump onto the high pressure sensor assembly
    DI620 HP Sensor Assembly 5
  34. Fit the pump onto the sump
    DI620 HP Sensor Assembly 4
  35. Tighten the jubilee clip retaining the pump to sump
    DI620 HP Sensor Assembly 1
  36. Tighten the jubilee clip retaining the pump to high pressure sensor assembly
    DI620 HP Sensor Assembly 2
  37. Replace the wires to the micro switch on the overflow unit 
    DI620 Overflow Container 2
  38. Wires attached
    DI620 Overflow Container 1
  39. Replace the base
    DI620 Base 4
  40. Using the phillips screwdriver replace the base retaining screw
    DI620 Base 3
  41. Replace further base retaining screws
    DI620 Base 2
  42. Now stand the appliance upright
    DI620 Base 1a
  43.  The appliance is now ready for use
    D1620 Door Image

     

Disclaimer: The information provided has been prepared as a guide only and the steps taken are likely to vary for different appliance models. We strongly recommend using a qualified engineer to undertake major repairs and fault finding.